Furman F1500-UPS E Battery Backup Power Conditioner
Taxes included.
Shipping calculated at checkout.
Standard delivery within 2–5 business days
Furman F1500-UPS E Battery Backup
Features
-
1500VA Battery Backup maintains critical data and allows orderly shutdown in
the event of a power outage - Series Multi-Stage Protection (SMP) provides virtually maintenance-free AC surge suppression
- Linear Filtering Technology (LiFT) for unequaled audio/video clarity
- Extreme Voltage Shutdown (EVS) protects your equipment from sustained overvoltage conditions
- Dual Learning IR Blasters allow safe shutdown of remote components
- RS-232 Interface provides custom open source programming and control
- USB Interface
- Critical Load Management
- AVR voltage regulation provides a consistent voltage output
- BlueBOLT® technology (with optional TCP/IP card, sold separately) provides remote control to reboot components, power equipment on or off, and monitor power quality from anywhere in the world
- Optional rack ears included
Protection
Typical UPS systems feature antiquated surge suppression technologies that can cause as much damage and annoying lock-ups as they attempt to prevent. Only Furman offers battery back-up with our road-proven SMP non-sacrificial, zero ground contamination surge suppression technology and EVS Extreme Voltage Shutdown. After all, the most robust battery cannot function if the accompanying circuits are damaged. With Furman's F1500-UPS E, you can expect years of trouble free operation*.
Filtration
While other UPS devices feature AC line filters suitable for an I.T. closet, only Furman employs our exclusive Linear Filtering Technology (LiFT). This advanced noise filtering technology assures that today's ultra-wide dynamic range is maintained as it must be – pristine. Remember, less AC noise equals greater content, greater resolution, and higher definition.
True Sine Wave Output
The F1500-UPS E provides True Sine Wave output when in battery backup mode, ensuring the utmost reliability to all connected equipment while running on battery power.
Expandability
At 1500VA, the F1500-UPS E provides substantial backup time for most critical digital A/V components. If more runtime is needed, a 1500VA battery pack (BATT1500-EXT, sold separately) may be used to further increase runtime (up to four times) as the application demands.
BlueBOLT® Cloud Based IP Control/Monitoring and Serial Programmability & Control
BlueBOLT compatibility (via BlueBOLT-CV1 interface card, sold separately), offers remote control over any Internet connection via a truly plug-and-play, hosted, web-based graphical user interface, with full control and power monitoring functionality. RS-232 control with a wide range of commands to interface with an existing control unit is included. Dual programmable IR control allows the unit to send a shut down command to remote components in the event of a blackout.
Typical Backup Components
Given the nature of battery backup technology, high-current audio and video components such as power amplifiers, powered subwoofers, and high- wattage displays are not recommended for use with the F1500-UPS E. Not only will these components drain battery power quite rapidly, line impedance will be raised due to the F1500-UPS E's (or any) AVR and AC to DC inverter, which can induce current compression and noticeably diminish performance with high-current A/V equipment. The following components are ideal for use with the F1500-UPS E:
- DAWs
- Satellite Receivers
- Cable Boxes
- Digital Video Recorders
- Media Servers
- External Hard Drives
- Lamp Based Video Displays
- Control Systems
For power management of other components, Furman recommends Classic, Prestige or Reference i Series Power Conditioners. For high-current components such as power amplifiers and powered subwoofers, solutions featuring Furman's exclusive Power Factor Technology are ideal.
Approximate Run Time, 1500VA *
Satellite Receiver or Cable Box = 80 Minutes
Media Server + Control System = 40 Minutes
Digital Mixing Console (24 Channel) = 20 minutes
DAW Computer + Digital I/O + External Hard Drive + 24” LCD Monitor = 12 Minutes
Specifiations:
| Nominal Line Voltage: | 220 VAC | 230 VAC | 240 VAC |
|
UPS Input |
|||
| Voltage: | 156 - 274 VAC | 166 - 284 VAC | 176 - 294 VAC |
| Frequency: | 50/60 Hz ±3% (auto-sensing) | ||
| UPS Output | |||
| Voltage: | 220 VAC ±10% | 230 VAC ±10% | 240 VAC ±10% |
| Frequency: | 50/60 Hz ±1% (adaptive) | ||
| Current Rating: | 6.82 A | 6.53 A | 6.25 A |
| UPS Output Capacity: | 1500 VA, 900W, cos 0.6 | ||
| UPS Backup Time: | 12 minutes at full load, 32 minutes at half load | ||
| UPS Transfer Time: | < 4ms | ||
| Automatic Voltage Regulation | |||
| Standard Mode Capture Range: | 160-276 VAC | 170-286 VAC | 180-296 VAC |
| Standard Mode Output Range: | 220 ± 24 VAC | 230 ± 24 VAC | 240 ± 24 VAC |
| Sensitive Mode Capture Range: | 177-254 VAC | 187-254 VAC | 197-264 VAC |
| Sensitive Mode Output Range: | 220 ± 12 VAC | 230 ± 12 VAC | 240 ± 12 VAC |
| Nominal Line Voltage: | 220 VAC | 230 VAC | 240 VAC |
|
Surge Protection |
|||
| Technology: | Non-sacrificial SMP (Series Multi-Stage Protection) | ||
| Overvoltage Shutoff, fast rise: | 305 VAC | ||
| Overvoltage Shutoff, slow rise: | 265 VAC | 275 VAC | 285 VAC |
| Noise Attenuation: | INPUT 10 dB @ 10kHz, 40 dB @ 100 kHz, 50 dB @ 500kHz | ||
| Linear Attenuation Curve: | From 0.05 - 100 Ohms line impedance | ||
|
UPS Physical Attributes |
|||
| UPS Topology: | Line Interactive | ||
| Temperature Rating: | 0 ~ 40°C / 40°C maximum for ambient operation | ||
| Mass: | 32.5 Kg / 72 lbs. | ||
| Dimensions: | 89mm H x 487.7mm L x 444.5mm D / 3.5" H x 19.2" L x 17" W | ||
| Battery: | Sealed Lead-Acid | ||
| Plug: | 1mm² x 3.3m, Detachable male Schuko with retention clips | ||
| Display: | Alphanumeric 2 X 20 LCD STN positive image, Backlit blue | ||
Caring for your Speakers and Amplifiers
To Keep your equipment safe these are some best practices to note. Please be advised that this is only to reduce the risk of misuse and is not an exhaustive list.
Speakers
- Speaker terminals are marked red and black, ensure your amplifier to the speakers are wired on the same colours
- Ensure no loose speaker wire from the red touches a loose wire from the black as this will lead to a short circuit and damage either the speaker, the amplifier or both.
- Not all speakers are designed to play at max volume, kindly consider the pairing of your amplifier and speakers
- Speaker cabinets cannot be replaced please handle with care.
AV & Stereo Amplifiers
- If your amplifier has HDMI ports, ensure all devices are off before plugging in the HDMI cable
- Turn off the amplifier before swoping out or adding speaker cable
- Amplifiers generate heat, place them in a well ventilated space. if possible avoid having anything on top of the unit.
- adding a surge protector can assist with power dips which are likely to damage your devices. Isotek and Furman are industry standard.
- Dusty environments can sometimes lead to accumulation of dust in the electronic components that might affect heat regulation
Shipping & Returns
- Free shipping on orders over R500 within the country.
- Standard delivery within 2–5 business days. Delays will be communicated. This might vary slightly depending on your location.
- Return items in original condition for a full refund. (unopened state)
- Returns that are open/unboxed will be subject to a handling fee. Refunds will only be processed after testing the unit.